Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2021-22811

6.1 · MEDIUM
Published Jan 28, 2022 schneider-electric CWE-79 EPSS 0.74% (52th pctl)

Overview

CVE-2021-22811 is a medium-severity vulnerability affecting schneider-electric network_management_card_2_firmware. It was published on January 28, 2022 and has a CVSS 3.1 base score of 6.1 (MEDIUM).

This vulnerability has a CVSS 3.1 base score of 6.1, rated MEDIUM. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NM

Remediation

Check the references section for vendor advisories and patches from schneider-electric. Update network_management_card_2_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
schneider-electric network_management_card_2_firmware 0 Affected

Frequently Asked Questions

What is CVE-2021-22811?

CVE-2021-22811 is a medium-severity vulnerability affecting schneider-electric network_management_card_2_firmware. It was published on January 28, 2022 and has a CVSS 3.1 base score of 6.1 (MEDIUM).

How severe is CVE-2021-22811?

This vulnerability has a CVSS 3.1 base score of 6.1, rated MEDIUM. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2021-22811?

Check the references section for vendor advisories and patches from schneider-electric. Update network_management_card_2_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2021-22811?

CyberStrike's AI-powered security agents can automatically detect CVE-2021-22811 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.