Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2025-54801

7.5 · HIGH
Published Aug 6, 2025 gofiber CWE-789 EPSS 0.36% (28th pctl)

Overview

CVE-2025-54801 is a high-severity vulnerability affecting gofiber fiber. It was published on August 6, 2025 and has a CVSS 3.1 base score of 7.5 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

Fiber is an Express inspired web framework written in Go. In versions 2.52.8 and below, when using Fiber's Ctx.BodyParser to parse form data containing a large numeric key that represents a slice index (e.g., test.18446744073704), the application crashes due to an out-of-bounds slice allocation in the underlying schema decoder. The root cause is that the decoder attempts to allocate a slice of length idx + 1 without validating whether the index is within a safe or reasonable range. If the idx is excessively large, this leads to an integer overflow or memory exhaustion, causing a panic or crash. This is fixed in version 2.52.9.

Remediation

Check the references section for vendor advisories and patches from gofiber. Update fiber to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
gofiber fiber >= 0, < 2.52.9 Affected

Frequently Asked Questions

What is CVE-2025-54801?

CVE-2025-54801 is a high-severity vulnerability affecting gofiber fiber. It was published on August 6, 2025 and has a CVSS 3.1 base score of 7.5 (HIGH).

How severe is CVE-2025-54801?

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2025-54801?

Check the references section for vendor advisories and patches from gofiber. Update fiber to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2025-54801?

CyberStrike's AI-powered security agents can automatically detect CVE-2025-54801 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.