CVE-2017-10722

7.8 · HIGH
Published Jun 17, 2019 ishekar CWE-119 EPSS 0.73% (52th pctl)

Overview

CVE-2017-10722 is a high-severity vulnerability affecting ishekar endoscope_camera_firmware. It was published on June 17, 2019 and has a CVSS 3.0 base score of 7.8 (HIGH).

This vulnerability has a CVSS 3.0 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi password. This application is installed on the device and an attacker who can provide the right payload can execute code on the user's system directly. Any breach of this system can allow an attacker to get access to all the data that the user has access too. The application uses a dynamic link library(DLL) called "avilib.dll" which is used by the application to send binary packets to the device that allow to control the device. One such action that the DLL provides is change password in the function "sendchangepass" which allows a user to change the Wi-Fi password on the device. This function calls a sub function "sub_75876EA0" at address 0x7587857C. The function determines which action to execute based on the parameters sent

Remediation

Check the references section for vendor advisories and patches from ishekar. Update endoscope_camera_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2017-10722?

CVE-2017-10722 is a high-severity vulnerability affecting ishekar endoscope_camera_firmware. It was published on June 17, 2019 and has a CVSS 3.0 base score of 7.8 (HIGH).

How severe is CVE-2017-10722?

This vulnerability has a CVSS 3.0 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2017-10722?

Check the references section for vendor advisories and patches from ishekar. Update endoscope_camera_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2017-10722?

CyberStrike's AI-powered security agents can automatically detect CVE-2017-10722 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.