CVE-2018-11464

3.7 · LOW
Published Dec 12, 2018 siemens CWE-248 EPSS 1.86% (78th pctl)

Overview

CVE-2018-11464 is a low-severity vulnerability affecting siemens sinumerik_828d_firmware. It was published on December 12, 2018 and has a CVSS 3.0 base score of 3.7 (LOW).

This vulnerability has a CVSS 3.0 base score of 3.7, rated LOW. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.

Remediation

Check the references section for vendor advisories and patches from siemens. Update sinumerik_828d_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
siemens sinumerik_828d_firmware 0 Affected
siemens sinumerik_840d_sl_firmware 0 Affected

Frequently Asked Questions

What is CVE-2018-11464?

CVE-2018-11464 is a low-severity vulnerability affecting siemens sinumerik_828d_firmware. It was published on December 12, 2018 and has a CVSS 3.0 base score of 3.7 (LOW).

How severe is CVE-2018-11464?

This vulnerability has a CVSS 3.0 base score of 3.7, rated LOW. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2018-11464?

Check the references section for vendor advisories and patches from siemens. Update sinumerik_828d_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2018-11464?

CyberStrike's AI-powered security agents can automatically detect CVE-2018-11464 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.