Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2019-14926

9.8 · CRITICAL
Published Oct 28, 2019 mitsubishielectric CWE-798 EPSS 2.08% (80th pctl)

Overview

CVE-2019-14926 is a critical-severity vulnerability affecting mitsubishielectric smartrtu_firmware. It was published on October 28, 2019 and has a CVSS 3.1 base score of 9.8 (CRITICAL).

This vulnerability has a CVSS 3.1 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware updates. In other words, these devices use private-key values in /etc/ssh/ssh_host_rsa_key, /etc/ssh/ssh_host_ecdsa_key, and /etc/ssh/ssh_host_dsa_key files that are publicly available from the vendor web sites.

Remediation

Check the references section for vendor advisories and patches from mitsubishielectric. Update smartrtu_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
mitsubishielectric smartrtu_firmware 0 Affected
inea me-rtu_firmware 0 Affected

Frequently Asked Questions

What is CVE-2019-14926?

CVE-2019-14926 is a critical-severity vulnerability affecting mitsubishielectric smartrtu_firmware. It was published on October 28, 2019 and has a CVSS 3.1 base score of 9.8 (CRITICAL).

How severe is CVE-2019-14926?

This vulnerability has a CVSS 3.1 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2019-14926?

Check the references section for vendor advisories and patches from mitsubishielectric. Update smartrtu_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2019-14926?

CyberStrike's AI-powered security agents can automatically detect CVE-2019-14926 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.