Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2019-6569

9.1 · CRITICAL
Published Mar 26, 2019 siemens CWE-440 EPSS 1.33% (69th pctl)

Overview

CVE-2019-6569 is a critical-severity vulnerability affecting siemens scalance_x-200_firmware. It was published on March 26, 2019 and has a CVSS 3.1 base score of 9.1 (CRITICAL).

This vulnerability has a CVSS 3.1 base score of 9.1, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.

Remediation

Check the references section for vendor advisories and patches from siemens. Update scalance_x-200_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
siemens scalance_x-200_firmware >= 0, < 5.2.4 Affected
siemens scalance_x-300_firmware >= 0, < 4.1.3 Affected
siemens scalance_xp-200_firmware >= 0, < 4.1 Affected
siemens scalance_xc-200_firmware >= 0, < 4.1 Affected
siemens scalance_xf-200_firmware >= 0, < 4.1 Affected

Frequently Asked Questions

What is CVE-2019-6569?

CVE-2019-6569 is a critical-severity vulnerability affecting siemens scalance_x-200_firmware. It was published on March 26, 2019 and has a CVSS 3.1 base score of 9.1 (CRITICAL).

How severe is CVE-2019-6569?

This vulnerability has a CVSS 3.1 base score of 9.1, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2019-6569?

Check the references section for vendor advisories and patches from siemens. Update scalance_x-200_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2019-6569?

CyberStrike's AI-powered security agents can automatically detect CVE-2019-6569 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.