CVE-2020-12510

7.3 · HIGH
Published Nov 19, 2020 beckhoff CWE-276 EPSS 0.88% (56th pctl)

Overview

CVE-2020-12510 is a high-severity vulnerability affecting beckhoff twincat_extended_automation_runtime. It was published on November 19, 2020 and has a CVSS 3.1 base score of 7.3 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.3, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

The default installation path of the TwinCAT XAR 3.1 software in all versions is underneath C:\TwinCAT. If the directory does not exist it and further subdirectories are created with permissions which allow every local user to modify the content. The default installation registers TcSysUI.exe for automatic execution upon log in of a user. If a less privileged user has a local account he or she can replace TcSysUI.exe. It will be executed automatically by another user during login. This is also true for users with administrative access. Consequently, a less privileged user can trick a higher privileged user into executing code he or she modified this way. By default Beckhoff’s IPCs are shipped with TwinCAT software installed this way and with just a single local user configured. Thus the vulnerability exists if further less privileged users have been added.

Remediation

Check the references section for vendor advisories and patches from beckhoff. Update twincat_extended_automation_runtime to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2020-12510?

CVE-2020-12510 is a high-severity vulnerability affecting beckhoff twincat_extended_automation_runtime. It was published on November 19, 2020 and has a CVSS 3.1 base score of 7.3 (HIGH).

How severe is CVE-2020-12510?

This vulnerability has a CVSS 3.1 base score of 7.3, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2020-12510?

Check the references section for vendor advisories and patches from beckhoff. Update twincat_extended_automation_runtime to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2020-12510?

CyberStrike's AI-powered security agents can automatically detect CVE-2020-12510 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.