Menu

Star on GitHub · 3.4k

CVE-2021-27196

7.5 · HIGH

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600…

Published Jun 14, 2021CWE-20EPSS 1.57%

Overview

CVE-2021-27196 is a high-severity vulnerability. It was published on June 14, 2021 and has a CVSS 3.1 base score of 7.5 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical description

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.

Remediation

Check the references section for vendor advisories, patches, and mitigation guidance. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Frequently asked questions

What is CVE-2021-27196?

CVE-2021-27196 is a high-severity vulnerability. It was published on June 14, 2021 and has a CVSS 3.1 base score of 7.5 (HIGH).

How severe is CVE-2021-27196?

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2021-27196?

Check the references section for vendor advisories, patches, and mitigation guidance. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2021-27196?

CyberStrike is an open-source, AI-augmented pentesting engine. Rather than flag a version number, it tests whether an issue like CVE-2021-27196 is actually reachable in your own applications and APIs, then verifies each finding before reporting it. That tells you if the weakness is a real, exploitable risk in your environment or a false positive you can safely deprioritize.

Related HIGH CVEs from 2021

View all
Watch the demo →