CVE-2021-27385

7.5 · HIGH
Published May 12, 2021 siemens CWE-400 EPSS 2.56% (84th pctl)

Overview

CVE-2021-27385 is a high-severity vulnerability affecting siemens simatic_wincc_runtime_advanced. It was published on May 12, 2021 and has a CVSS 3.1 base score of 7.5 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMI

Remediation

Check the references section for vendor advisories and patches from siemens. Update simatic_wincc_runtime_advanced to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
siemens simatic_wincc_runtime_advanced >= 0, < 16 Affected
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware >= 0, < 16 Affected
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware >= 0, < 16 Affected

Frequently Asked Questions

What is CVE-2021-27385?

CVE-2021-27385 is a high-severity vulnerability affecting siemens simatic_wincc_runtime_advanced. It was published on May 12, 2021 and has a CVSS 3.1 base score of 7.5 (HIGH).

How severe is CVE-2021-27385?

This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2021-27385?

Check the references section for vendor advisories and patches from siemens. Update simatic_wincc_runtime_advanced to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2021-27385?

CyberStrike's AI-powered security agents can automatically detect CVE-2021-27385 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.