Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2021-29075

8.4 · HIGH
Published Mar 23, 2021 netgear CWE-787 EPSS 0.40% (33th pctl)

Overview

CVE-2021-29075 is a high-severity vulnerability affecting netgear rbw30_firmware. It was published on March 23, 2021 and has a CVSS 3.1 base score of 8.4 (HIGH).

This vulnerability has a CVSS 3.1 base score of 8.4, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12.

Remediation

Check the references section for vendor advisories and patches from netgear. Update rbw30_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
netgear rbw30_firmware >= 0, < 2.6.2.2 Affected
netgear rbk852_firmware >= 0, < 3.2.17.12 Affected
netgear rbk853_firmware >= 0, < 3.2.17.12 Affected
netgear rbk854_firmware >= 0, < 3.2.17.12 Affected
netgear rbr850_firmware >= 0, < 3.2.17.12 Affected
netgear rbs850_firmware >= 0, < 3.2.17.12 Affected
netgear rbk752_firmware >= 0, < 3.2.17.12 Affected
netgear rbk753_firmware >= 0, < 3.2.17.12 Affected
netgear rbk753s_firmware >= 0, < 3.2.17.12 Affected
netgear rbk754_firmware >= 0, < 3.2.17.12 Affected

Frequently Asked Questions

What is CVE-2021-29075?

CVE-2021-29075 is a high-severity vulnerability affecting netgear rbw30_firmware. It was published on March 23, 2021 and has a CVSS 3.1 base score of 8.4 (HIGH).

How severe is CVE-2021-29075?

This vulnerability has a CVSS 3.1 base score of 8.4, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2021-29075?

Check the references section for vendor advisories and patches from netgear. Update rbw30_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2021-29075?

CyberStrike's AI-powered security agents can automatically detect CVE-2021-29075 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.