Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2022-22805

9.8 · CRITICAL
Published Mar 9, 2022 schneider-electric CWE-120 EPSS 11.66% (96th pctl)

Overview

CVE-2022-22805 is a critical-severity vulnerability affecting schneider-electric smt_series_1015_ups_firmware. It was published on March 9, 2022 and has a CVSS 3.1 base score of 9.8 (CRITICAL).

This vulnerability has a CVSS 3.1 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

Remediation

Check the references section for vendor advisories and patches from schneider-electric. Update smt_series_1015_ups_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
schneider-electric smt_series_1015_ups_firmware 0 Affected
schneider-electric smc_series_1018_ups_firmware 0 Affected
schneider-electric smtl_series_1026_ups_firmware 0 Affected
schneider-electric scl_series_1029_ups_firmware 0 Affected
schneider-electric scl_series_1030_ups_firmware 0 Affected
schneider-electric scl_series_1036_ups_firmware 0 Affected
schneider-electric scl_series_1037_ups_firmware 0 Affected
schneider-electric smx_series_1031_ups_firmware 0 Affected

Frequently Asked Questions

What is CVE-2022-22805?

CVE-2022-22805 is a critical-severity vulnerability affecting schneider-electric smt_series_1015_ups_firmware. It was published on March 9, 2022 and has a CVSS 3.1 base score of 9.8 (CRITICAL).

How severe is CVE-2022-22805?

This vulnerability has a CVSS 3.1 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2022-22805?

Check the references section for vendor advisories and patches from schneider-electric. Update smt_series_1015_ups_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2022-22805?

CyberStrike's AI-powered security agents can automatically detect CVE-2022-22805 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.