CVE-2024-39701

6.3 · MEDIUM
Published Jul 8, 2024 monospace CWE-284 EPSS 0.42% (35th pctl)

Overview

CVE-2024-39701 is a medium-severity vulnerability affecting monospace directus. It was published on July 8, 2024 and has a CVSS 3.1 base score of 6.3 (MEDIUM).

This vulnerability has a CVSS 3.1 base score of 6.3, rated MEDIUM. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

Technical Description

Directus is a real-time API and App dashboard for managing SQL database content. Directus >=9.23.0, <=v10.5.3 improperly handles _in, _nin operators. It evaluates empty arrays as valid so expressions like {"role": {"_in": $CURRENT_USER.some_field}} would evaluate to true allowing the request to pass. This results in Broken Access Control because the rule fails to do what it was intended to do: Pass rule if **field** matches any of the **values**. This vulnerability is fixed in 10.6.0.

Remediation

Check the references section for vendor advisories and patches from monospace. Update directus to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
monospace directus >= 9.23.0, < 10.6.0 Affected

Frequently Asked Questions

What is CVE-2024-39701?

CVE-2024-39701 is a medium-severity vulnerability affecting monospace directus. It was published on July 8, 2024 and has a CVSS 3.1 base score of 6.3 (MEDIUM).

How severe is CVE-2024-39701?

This vulnerability has a CVSS 3.1 base score of 6.3, rated MEDIUM. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2024-39701?

Check the references section for vendor advisories and patches from monospace. Update directus to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2024-39701?

CyberStrike's AI-powered security agents can automatically detect CVE-2024-39701 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.