Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2024-7915

7.8 · HIGH
Published Nov 25, 2024 CWE-863 EPSS 0.15% (5th pctl)

Overview

CVE-2024-7915 is a high-severity vulnerability. It was published on November 25, 2024 and has a CVSS 3.1 base score of 7.8 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

The application Sensei Mac Cleaner contains a local privilege escalation vulnerability, allowing an attacker to perform multiple operations as the root user. These operations include arbitrary file deletion and writing, loading and unloading daemons, manipulating file permissions, and loading extensions, among other actions.

The vulnerable module org.cindori.SenseiHelper can be contacted via XPC. While the module performs client validation, it relies on the client's PID obtained through the public processIdentifier property of the NSXPCConnection class. This approach makes the module susceptible to a PID Reuse Attack, enabling an attacker to impersonate a legitimate client and send crafted XPC messages to invoke arbitrary methods exposed by the HelperProtocol interface.

Remediation

Check the references section for vendor advisories, patches, and mitigation guidance. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Frequently Asked Questions

What is CVE-2024-7915?

CVE-2024-7915 is a high-severity vulnerability. It was published on November 25, 2024 and has a CVSS 3.1 base score of 7.8 (HIGH).

How severe is CVE-2024-7915?

This vulnerability has a CVSS 3.1 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2024-7915?

Check the references section for vendor advisories, patches, and mitigation guidance. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2024-7915?

CyberStrike's AI-powered security agents can automatically detect CVE-2024-7915 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.