Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2025-15419

3.3 · LOW
Published Jan 2, 2026 open5gs CWE-404 EPSS 0.24% (14th pctl)

Overview

CVE-2025-15419 is a low-severity vulnerability affecting open5gs open5gs. It was published on January 2, 2026 and has a CVSS 3.1 base score of 3.3 (LOW).

This vulnerability has a CVSS 3.1 base score of 3.3, rated LOW. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

A weakness has been identified in Open5GS up to 2.7.6. Affected by this issue is the function sgwc_s5c_handle_create_session_response of the file src/sgwc/s5c-handler.c of the component GTPv2-C Flow Handler. Executing a manipulation can lead to denial of service. The attack needs to be launched locally. The exploit has been made available to the public and could be used for attacks. This patch is called 5aaa09907e7b9e0a326265a5f08d56f54280b5f2. It is advisable to implement a patch to correct this issue.

Remediation

Check the references section for vendor advisories and patches from open5gs. Update open5gs to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
open5gs open5gs 0 Affected

Frequently Asked Questions

What is CVE-2025-15419?

CVE-2025-15419 is a low-severity vulnerability affecting open5gs open5gs. It was published on January 2, 2026 and has a CVSS 3.1 base score of 3.3 (LOW).

How severe is CVE-2025-15419?

This vulnerability has a CVSS 3.1 base score of 3.3, rated LOW. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2025-15419?

Check the references section for vendor advisories and patches from open5gs. Update open5gs to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2025-15419?

CyberStrike's AI-powered security agents can automatically detect CVE-2025-15419 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.