7.7 · HIGH Actively ExploitedOverview
CVE-2025-20352 is a high-severity vulnerability affecting cisco ios_xe_sd-wan. It was published on September 24, 2025 and has a CVSS 3.1 base score of 7.7 (HIGH). This vulnerability is listed in CISA's Known Exploited Vulnerabilities catalog, indicating active exploitation in the wild.
This vulnerability has a CVSS 3.1 base score of 7.7, rated HIGH. It can be exploited remotely over the network. Some level of privileges is required for exploitation.
Technical Description
A vulnerability in the Simple Network Management Protocol (SNMP) subsystem of Cisco IOS Software and Cisco IOS XE Software could allow the following:
An authenticated, remote attacker with low privileges could cause a denial of service (DoS) condition on an affected device that is running Cisco IOS Software or Cisco IOS XE Software. To cause the DoS, the attacker must have the SNMPv2c or earlier read-only community string or valid SNMPv3 user credentials. An authenticated, remote attacker with high privileges could execute code as the root user on an affected device that is running Cisco IOS XE Software. To execute code as the root user, the attacker must have the SNMPv1 or v2c read-only community string or valid SNMPv3 user credentials and administrative or privilege 15 credentials on the affected device. An attacker could exploit this vulnerability by sending a crafted SNMP packet to an affected device over IPv4 or IPv6 networks.
This vulnerability is due to a stack ov
Remediation
Check the references section for vendor advisories and patches from cisco. Update ios_xe_sd-wan to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.
Affected Products
| Vendor | Product | Versions | Status |
|---|
Frequently Asked Questions
What is CVE-2025-20352?
CVE-2025-20352 is a high-severity vulnerability affecting cisco ios_xe_sd-wan. It was published on September 24, 2025 and has a CVSS 3.1 base score of 7.7 (HIGH). This vulnerability is listed in CISA's Known Exploited Vulnerabilities catalog, indicating active exploitation in the wild.
How severe is CVE-2025-20352?
This vulnerability has a CVSS 3.1 base score of 7.7, rated HIGH. It can be exploited remotely over the network. Some level of privileges is required for exploitation.
How do I fix or remediate CVE-2025-20352?
Check the references section for vendor advisories and patches from cisco. Update ios_xe_sd-wan to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.
How can CyberStrike help with CVE-2025-20352?
CyberStrike's AI-powered security agents can automatically detect CVE-2025-20352 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.
How CyberStrike Helps
AI agents map your attack surface to find vulnerabilities like this one.
Automated penetration testing that runs continuously, not just quarterly.
AI-driven PR review catches vulnerable dependencies before they ship.
Browser-based exploitation validates findings with real proof-of-concept.
Related HIGH CVEs from 2025
View all →HCL MyXalytics is affected by out-of-band resource load (HTTP) vulnerability. An attacker can deplo
The NextEPC MME <= 1.0.1 (fixed in commit a8492c9c5bc0a66c6999cb5a263545b32a4109df) contains a stack
A flaw was found in the Red Hat Advanced Cluster Security (RHACS) portal. When rendering a table vie
A Stored Cross-Site Scripting (XSS) vulnerability exists in the chat file upload functionality of op
A: Improper Neutralization of Input During Web Page Generation vulnerability in SUSE rancher allows
Mbed TLS before 3.6.4 allows a use-after-free in certain situations of applications that are develop
In iperf before 3.19.1, net.c has a buffer overflow when --skip-rx-copy is used (for MSG_TRUNC in re
Missing authorization in Ivanti Connect Secure before 22.7R2.9 or 22.8R2, Ivanti Policy Secure befor
Memory corruptions can be remotely triggered in the Control-M/Agent when SSL/TLS communication is co
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerab
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerab
An issue in Orban Optimod 5950, Optimod 5950HD, Optimod 5750, Optimod 5750HD, Optimod Trio Optimod v