CVE-2025-34205

9.8 · CRITICAL
Published Sep 19, 2025 vasion CWE-561 EPSS 1.41% (71th pctl)

Overview

CVE-2025-34205 is a critical-severity vulnerability affecting vasion virtual_appliance_application. It was published on September 19, 2025 and has a CVSS 3.1 base score of 9.8 (CRITICAL).

This vulnerability has a CVSS 3.1 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 22.0.843 and Application prior to 20.0.1923 (VA and SaaS deployments) contains dangerous PHP dead code present in multiple Docker-hosted PHP instances. A script named /var/www/app/resetroot.php (found in several containers) lacks authentication checks and, when executed, performs a SQL update that sets the database administrator username to 'root' and its password hash to the SHA-512 hash of the string 'password'. Separately, commented-out code in /var/www/app/lib/common/oses.php would unserialize session data (unserialize($_SESSION['osdata']))—a pattern that can enable remote code execution if re-enabled or reached with attacker-controlled serialized data. An attacker able to reach the resetroot.php endpoint can trivially reset the MySQL root password and obtain full database control; combined with deserialization issues this can lead to full remote code execution and system compromise. This vulnerability ha

Remediation

Check the references section for vendor advisories and patches from vasion. Update virtual_appliance_application to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
vasion virtual_appliance_application >= 0, < 20.0.1923 Affected
vasion virtual_appliance_host >= 0, < 22.0.843 Affected

Frequently Asked Questions

What is CVE-2025-34205?

CVE-2025-34205 is a critical-severity vulnerability affecting vasion virtual_appliance_application. It was published on September 19, 2025 and has a CVSS 3.1 base score of 9.8 (CRITICAL).

How severe is CVE-2025-34205?

This vulnerability has a CVSS 3.1 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2025-34205?

Check the references section for vendor advisories and patches from vasion. Update virtual_appliance_application to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2025-34205?

CyberStrike's AI-powered security agents can automatically detect CVE-2025-34205 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.