CVE-2025-34234
7.5 · HIGHOverview
CVE-2025-34234 is a high-severity vulnerability affecting vasion virtual_appliance_application. It was published on September 29, 2025 and has a CVSS 3.1 base score of 7.5 (HIGH).
This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.
Technical Description
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 25.1.102 and Application prior to version 25.1.1413 (VA/SaaS deployments) contain two hardcoded private keys that are shipped in the application containers (printerlogic/pi, printerlogic/printer-admin-api, and printercloud/pi). The keys are stored in clear text under /var/www/app/config/ as keyfile.ppk.dev and keyfile.saasid.ppk.dev. The application uses these keys as the symmetric secret for AES‑256‑CBC encryption/decryption of the “SaaS Id” (external identifier) through the getEncryptedExternalId() / getDecryptedExternalId() methods. Because the secret is embedded in the deployed image, any attacker who can obtain a copy of the Docker image, read the configuration files, or otherwise enumerate the filesystem can recover the encryption key. This vulnerability has been confirmed to be remediated, but it is unclear as to when the patch was introduced.
Remediation
Check the references section for vendor advisories and patches from vasion. Update virtual_appliance_application to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.
Affected Products
| Vendor | Product | Versions | Status |
|---|---|---|---|
| vasion | virtual_appliance_application | >= 0, < 25.1.1413 | Affected |
| vasion | virtual_appliance_host | >= 0, < 25.1.102 | Affected |
References
Frequently Asked Questions
What is CVE-2025-34234?
CVE-2025-34234 is a high-severity vulnerability affecting vasion virtual_appliance_application. It was published on September 29, 2025 and has a CVSS 3.1 base score of 7.5 (HIGH).
How severe is CVE-2025-34234?
This vulnerability has a CVSS 3.1 base score of 7.5, rated HIGH. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.
How do I fix or remediate CVE-2025-34234?
Check the references section for vendor advisories and patches from vasion. Update virtual_appliance_application to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.
How can CyberStrike help with CVE-2025-34234?
CyberStrike's AI-powered security agents can automatically detect CVE-2025-34234 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.
How CyberStrike Helps
AI agents map your attack surface to find vulnerabilities like this one.
Automated penetration testing that runs continuously, not just quarterly.
AI-driven PR review catches vulnerable dependencies before they ship.
Browser-based exploitation validates findings with real proof-of-concept.
Related HIGH CVEs from 2025
View all →HCL MyXalytics is affected by out-of-band resource load (HTTP) vulnerability. An attacker can deplo
The NextEPC MME <= 1.0.1 (fixed in commit a8492c9c5bc0a66c6999cb5a263545b32a4109df) contains a stack
A flaw was found in the Red Hat Advanced Cluster Security (RHACS) portal. When rendering a table vie
A Stored Cross-Site Scripting (XSS) vulnerability exists in the chat file upload functionality of op
A: Improper Neutralization of Input During Web Page Generation vulnerability in SUSE rancher allows
Mbed TLS before 3.6.4 allows a use-after-free in certain situations of applications that are develop
In iperf before 3.19.1, net.c has a buffer overflow when --skip-rx-copy is used (for MSG_TRUNC in re
Missing authorization in Ivanti Connect Secure before 22.7R2.9 or 22.8R2, Ivanti Policy Secure befor
Memory corruptions can be remotely triggered in the Control-M/Agent when SSL/TLS communication is co
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerab
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerab
An issue in Orban Optimod 5950, Optimod 5950HD, Optimod 5750, Optimod 5750HD, Optimod Trio Optimod v