Overview

CVE-2025-71336 is a critical-severity vulnerability affecting flowiseai flowise. It was published on June 25, 2026 and has a CVSS 3.1 base score of 9.8 (CRITICAL).

This vulnerability has a CVSS 3.1 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

Flowise before 3.0.6 (affected versions 2.2.7-patch.1 and earlier) contains an unsandboxed remote code execution vulnerability in the Custom MCP feature, which is designed to execute OS commands such as launching local MCP servers. Because Flowise's authentication and authorization model is minimal and lacks role-based access control, and the default installation runs without authentication unless FLOWISE_USERNAME and FLOWISE_PASSWORD are set, an attacker can send a crafted JSON payload with the header 'x-request-from: internal' to the /api/v1/node-load-method/customMCP endpoint to execute arbitrary OS commands, resulting in complete compromise of the platform container or server.

Remediation

Check the references section for vendor advisories and patches from flowiseai. Update flowise to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
flowiseai flowise >= 0, < 3.0.6 Affected

Frequently Asked Questions

What is CVE-2025-71336?

CVE-2025-71336 is a critical-severity vulnerability affecting flowiseai flowise. It was published on June 25, 2026 and has a CVSS 3.1 base score of 9.8 (CRITICAL).

How severe is CVE-2025-71336?

This vulnerability has a CVSS 3.1 base score of 9.8, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2025-71336?

Check the references section for vendor advisories and patches from flowiseai. Update flowise to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2025-71336?

CyberStrike's AI-powered security agents can automatically detect CVE-2025-71336 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.