CVE-2026-29120

7.8 · HIGH
Published Mar 4, 2026 datacast CWE-798

Overview

CVE-2026-29120 is a high-severity vulnerability affecting datacast sfx2100_firmware. It was published on March 4, 2026 and has a CVSS 3.1 base score of 7.8 (HIGH).

This vulnerability has a CVSS 3.1 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

Technical Description

The /root/anaconda-ks.cfg installation configuration file in International Datacasting Corporation (IDC) SFX Series(SFX2100) SuperFlex Satellite Receiver insecurely stores the hardcoded root password hash. The password itself is highly insecure and susceptible to offline dictionary attacks using the rockyou.txt wordlist. Because direct root SSH login is disabled, an attacker must first obtain low-privileged access to the system (e.g., via other vulnerabilities) to be able to log in as the root user. The password is hardcoded and so allows for an actor with local access on effected versions to escalate to root

Remediation

Check the references section for vendor advisories and patches from datacast. Update sfx2100_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status

Frequently Asked Questions

What is CVE-2026-29120?

CVE-2026-29120 is a high-severity vulnerability affecting datacast sfx2100_firmware. It was published on March 4, 2026 and has a CVSS 3.1 base score of 7.8 (HIGH).

How severe is CVE-2026-29120?

This vulnerability has a CVSS 3.1 base score of 7.8, rated HIGH. It requires local or adjacent network access to exploit. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2026-29120?

Check the references section for vendor advisories and patches from datacast. Update sfx2100_firmware to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2026-29120?

CyberStrike's AI-powered security agents can automatically detect CVE-2026-29120 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.

Browse by year 2026