Skip to main content

Over 150 LLM Providers · Over 5,300 Models The most extensible AI-powered pentesting platform. Open source. Star on GitHub

CVE-2026-59151

9.6 · CRITICAL
Published Jul 10, 2026 prowler CWE-287

Overview

CVE-2026-59151 is a critical-severity vulnerability affecting prowler prowler. It was published on July 10, 2026 and has a CVSS 3.1 base score of 9.6 (CRITICAL).

This vulnerability has a CVSS 3.1 base score of 9.6, rated CRITICAL. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

Technical Description

Prowler is a cloud security platform. Prior to 5.30.3, Prowler's SAML authentication flow trusted the email domain asserted in a SAMLResponse when deciding which tenant should receive the final token, and the ACS finish logic in api/src/backend/api/v1/views.py recalculated the tenant from user.email instead of binding token issuance to the validated SAML configuration. An authenticated attacker with a controlled SAML IdP could complete a valid SAML flow for an attacker-controlled domain while asserting an email address from another configured domain, causing a SAMLToken and tenant-scoped JWT to be issued for the wrong tenant and enabling cross-tenant account takeover. This issue is fixed in version 5.30.3.

Remediation

Check the references section for vendor advisories and patches from prowler. Update prowler to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
prowler prowler >= 0, < 5.30.3 Affected

Frequently Asked Questions

What is CVE-2026-59151?

CVE-2026-59151 is a critical-severity vulnerability affecting prowler prowler. It was published on July 10, 2026 and has a CVSS 3.1 base score of 9.6 (CRITICAL).

How severe is CVE-2026-59151?

This vulnerability has a CVSS 3.1 base score of 9.6, rated CRITICAL. It can be exploited remotely over the network. Some level of privileges is required for exploitation.

How do I fix or remediate CVE-2026-59151?

Check the references section for vendor advisories and patches from prowler. Update prowler to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2026-59151?

CyberStrike's AI-powered security agents can automatically detect CVE-2026-59151 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.