CVE-2018-13799

9.1 · CRITICAL
Published Sep 12, 2018 siemens CWE-269 EPSS 2.25% (82th pctl)

Overview

CVE-2018-13799 is a critical-severity vulnerability affecting siemens simatic_wincc_open_architecture. It was published on September 12, 2018 and has a CVSS 3.0 base score of 9.1 (CRITICAL).

This vulnerability has a CVSS 3.0 base score of 9.1, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

Technical Description

A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow an attacker to compromise integrity and availability of the SIMATIC WinCC OA system. At the time of advisory publication no public exploitation of this vulnerability was known.

Remediation

Check the references section for vendor advisories and patches from siemens. Update simatic_wincc_open_architecture to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

Affected Products

Vendor Product Versions Status
siemens simatic_wincc_open_architecture 0 Affected

Frequently Asked Questions

What is CVE-2018-13799?

CVE-2018-13799 is a critical-severity vulnerability affecting siemens simatic_wincc_open_architecture. It was published on September 12, 2018 and has a CVSS 3.0 base score of 9.1 (CRITICAL).

How severe is CVE-2018-13799?

This vulnerability has a CVSS 3.0 base score of 9.1, rated CRITICAL. It can be exploited remotely over the network. No authentication or special privileges are required for exploitation.

How do I fix or remediate CVE-2018-13799?

Check the references section for vendor advisories and patches from siemens. Update simatic_wincc_open_architecture to the latest patched version. If immediate patching is not possible, review the CVSS vector to understand the attack surface and apply compensating controls such as network segmentation or access restrictions.

How can CyberStrike help with CVE-2018-13799?

CyberStrike's AI-powered security agents can automatically detect CVE-2018-13799 across your infrastructure using autonomous pentesting, DAST scanning, and HackBrowser. The platform continuously monitors for known vulnerabilities and provides actionable remediation guidance prioritized by real-world exploitability.